Vertical station (STAARQ)
Context:
Tests of large magnet components (h ≤ 7.9 m, Φ ≤ 882 mm, I < 20 kA) at low temperature (in liquid helium or under vacuum, T ≥ 1.8 K).
JT-60SA station
Context:
Trials on current intensity, insulation voltage, mechanical stress, pressure drop and temperature for large magnets (oblong cryostat, l ≤ 10 m, w ≤ 6.5 m, h ≤ 2 m) cooled with supercritical forced helium flow (5 K ≤ T ≤ 7.5 K).
Location
CEA - Saclay (France)
Contact
For further information please email: AMICI@cea.fr.